¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡BFD-03
Epoxy Polyurethane Light Colour Antistatic
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Oilproof Anti-corrosive Coating
1). Description of product:
The coating is a dual component coating composed of
epoxy resin, multi isocyanic ester addition compound,
tailor-made light-colour electric fillings, auxiliary
and mixing solvent, etc., possessing both epoxy resin
and polyurethane properties. The resistivity is according
with standards of GB13348-92.
This coating resin has excellent adhesion and protection
to light-colour electric fillings, anti- pervasion,
slippery paint film, anti-wear and don't pollute oil
product.
It could not only effectively prevent fire caused by
static electricity, but also possesses excellent oilproof
and anti-chemicals (such as acid, base and salt, etc.)
properties.
2). Designed usage: Inner anti-corrosive coating for
aviation kerosene, petrol and other military, and civil
product oil tanks, as well as relevant facilities.
3). Main specifications:
Main physical properties of coating and paint film
Item Unit BFD-03 Test method
With-rust primer Antirust primer Anti-corrosive finish
Appearance Henna Henna White or offwhite Visual inspection
Viscosity S¡Ý 55 55 55 GB/T 1723-93
Dry time h¡Ü Surface dry: 3, Full dry: 24 GB/T1728-89
Adhesion Grade 1~2 GB/T 1720-89
Flexibility mm 1~2 GB/T1731-93
Anti-impact J¡Ý 4.9 GB/T 1732-93
Surface resistivity ¦¸£¼ 1¡Á109 GB/T 16906-1997
¡ù Anti-petrol d Non-variation at normal temperature
180d coat GB/T 1734-93
¡ù Anti-diesel oil d Non-variation at normal temperature
180d coat GB/T 1734-93
¡ù Anti-aviation kerosene d Non-variation at normal temperature
180d coat GB/T 1734-93
¡ù 3% NaCl (normal temperature) d Non-variation at normal
temperature 30d coat GB/T 1763-93
¡ù 15% H2SO4 (normal temperature) d Non-variation at
normal temperature 30d coat GB/T 1763-93
¡ù 15% NaOH (normal temperature) d Non-variation at normal
temperature 30d coat GB/T 1763-93
¡ù 15%HCl (normal temperature) d Non-variation at normal
temperature 30d coat GB/T 1763-93
¡ù The test sample coats are complex coats of primer
plus finish, the thickness ¡Ý200¦Ìm.
4). Instruction for application:
4.1 Application condition: Ambient temperature is not
below -5¡æ, the relative humidity of air is not higher
than 75 %. But work should be stopped when it rains,
snows or it's foggy.
4.2 Surface treatment: for new steel structure, shotblasting
to Grade Sa2.5; for maintenance painting, rust is removed
mechanically to Grade St3 (with-rust primer is recommended),
clear away dust, iron chippings and greasy dirt after
surface treatment, and then paint in eight hours.
4.3 Applying method: Brush or roll painting manually,
and air or airless spray-painting as well.
4.4 Blending of coating: Mix component A with component
B in proportion, fully agitated, aging
for 30 minutes at air temperature of 25¡æ~35¡æ before
it is used. To prolong the aging time if it is below
25¡æ. Entering of water is strictly forbidden during
blending and brush painting.
4.5 Recommended applying scheme: primer: 2 paths, theory
consumption: 0.3 kg/m2 ; finish: 2~3 paths, theory consumption:
0.3 kg/m2~0.45 kg/m2. Total thickness of coat after
drying is large than
¡Ý160¦Ìm ~200¦Ìm.
4.6 Repainting interval: shortest: 6 hours; longest:
24 hours.
4.7 Usable life of coating: use up in 4 hours at air
temperature of 25¡æ; reduce usable life when air temperature
is above 25¡æ, and increase usable life when air temperature
is below 25¡æ.
4.8 Servicing duration: it should be no less than 10
days when ambient temperature is not below 25¡æ(the tank
could be packed with oil only after above 10 days from
the date of painting).
4.9 Thinner: The coating is used blending with thinner
X-02A. The consumption of thinner is about 5 % of coating.
In winter viscosity increases due to the cold weather,
the additive dosage is about
10 %~20 % of coating consumption.
5). Packing, storage and transportation:
Packed and sealed in iron drum, the net weight per drum
for component A is 20 kg¡À0.2 kg, component B is 7.0
kg¡À0.5 kg(variation of consumption depends on seasons
).
Be stored in shady, cool, dry and well-ventilated place,
away from fire and hot resources, and avoid dropping
in water. Preventing raining and solarization in transportation,
and should be in accord with standards of traffic department.
Upon the base of above condition and at normal temperature,
the effective storage period is one year from the date
of production.
6). Points for attention:
1. Fire is strictly prohibited on job-site, fire fighting
tools should be seated at convenient site.
2. Good lighting is needed at job-site. When operation
in the equipment, low-voltage power (12 volt) should
be employed.
3. When in bad ventilating work-site(such as: in the
tank or in basement), efficient ventilating and air
exhausting is necessary on the spot. The operator should
wear gas mask, and under the protection of special persons.
4. If headache, heart-throb or nausea happens, the operator
should leave the work-site immediately, and take rest
on well ventilated spot.
7). Product is accord with standards: Q/HHC 019-2003.
|